Blocking Performance Tester

Get personalized pricing for your specific requirements

Blocking Performance Tester - ToronMed™ BPT06

Evaluates the check valve performance of infusion equipment for medical use. This instrument identifies leakage and pressure stability in single-use fluid line components effectively. Precise absolute pressure sensors monitor valve closure behavior to ensure reliable blocking during clinical applications. Operators use the seven-inch touchscreen to manage test cycles and view real-time data curves.

Automated pass or fail judgments simplify quality control workflows for medical device manufacturers. Internal memory stores up to fifty thousand records for quick retrieval and historical data review. The system includes overvoltage protection to maintain operational stability during intensive research and development tasks. Standard RS232 interfaces allow for seamless data transfer to external laboratory information systems.

Features and Technical Advantages

  • High-Accuracy Sensing: Absolute pressure sensors and precision vacuum generators enhance measurement reliability for delicate components.

  • Customizable Parameters: Operators can preset specific pressure levels and test durations to meet diverse experimental requirements.

  • User-Friendly Interface: The 7-inch HD touchscreen provides clear visualizations of testing progress and analytical results.

  • Integrated Reporting: Built-in micro printers generate immediate documentation of valve performance and compliance status.

  • Robust Safety Design: Power-down memory functions protect valuable test data during unexpected electrical interruptions.

Specialized Medical Applications

Manufacturers utilize these testers to verify the integrity of check valves used with pressure infusion devices. Quality control laboratories perform routine inspections to confirm that fluid line components meet global safety requirements. Research facilities evaluate new valve designs for blocking efficiency and structural durability under controlled conditions. Regulatory teams rely on these accurate measurements to ensure compliance with ISO 8536-12 standards.

Technical Specifications

Specification

Value

Test Range

0–10 kPa (Standard)

Measurement Accuracy

0.5% FS

Gas Supply Pressure

≤ 0.7 MPa

Supply Port Size

Φ8 mm PU tubing

Interface Type

RS232 Serial Port

Data Capacity

50,000 Records

Voltage

220V 50Hz / 110V 60Hz

Standard Configuration

The primary configuration includes the main instrument unit, a high-resolution touchscreen interface, and a dedicated pressure tank. Each setup features a specialized sample holder designed to secure various infusion valve types during testing. Operators also receive a built-in micro printer for generating immediate validation reports on the laboratory floor.