{"product_id":"melting-point-apparatus-toronmpa-300","title":"Automatic Digital Melting Point Apparatus (360°C)","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eMelting Point Apparatus - ToronMPA™ 300\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eEvaluates melting behavior with traceable results. This fully automatic video-based system replaces traditional microscope viewing for APIs and excipients. Manufacturing facilities utilize these units for research and quality control across diverse industrial sectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHigh-definition camera modules facilitate phase transition observation during critical transitions. Integrated AI-assisted setups standardize routine method configurations for four-sample batches. Operators manage results through color touchscreens to verify endpoint decisions. Technical teams evaluate compounds and raw materials to monitor purity shifts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eTechnical Advantages\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAutomatic Recording:\u003c\/span\u003e\u003cspan\u003e Captures initial and final melt points with video documentation to verify transitions during compound synthesis.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eStandardized Setup:\u003c\/span\u003e\u003cspan\u003e Supports automated parameter configurations to simplify routine runs and maintain repeatability across laboratory sites.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRegulatory Readiness:\u003c\/span\u003e\u003cspan\u003e Features four-level authority management and audit tracking for controlled documentation and electronic signatures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eThermal Precision:\u003c\/span\u003e\u003cspan\u003e Maintains accurate temperature regulation using PID technology and programmable segments to align with SOP requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"151\"\u003e \u003ccol width=\"206\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTORONMPA 300\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDetection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFully Automatic Video-Based\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTemperature Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRoom Temp to 360 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0.01 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e±0.3 °C (at ≤200 °C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBatch Capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e4 Samples\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMapping Storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e20,000 Sets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eStandard Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eStandard configurations feature the main automatic instrument and specialized capillary tubes. Each package includes integrated camera modules and color touchscreens. Professional software manages PDF exports and audit trails. This setup validates material properties for food, drugs, spices, and dyes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":49650657296623,"sku":null,"price":57.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/melting-point-apparatus.webp?v=1784598190","url":"https:\/\/shop.torontech.com\/products\/melting-point-apparatus-toronmpa-300","provider":"Torontech","version":"1.0","type":"link"}