{"product_id":"3-cell-infrared-wvtr-tester-toronwvtr-ir3","title":"3-Cell Infrared WVTR Tester - ToronWVTR™ Ir3","description":"\u003cp\u003eThe ToronWVTR™ Ir3 triples your daily output when screening high-barrier wrapping sheets, inspecting three distinct samples simultaneously using optical infrared detection.\u003c\/p\u003e\n\u003cp\u003eBuilt around ASTM F1249 and ISO 15106-2 test standards, this three-chamber system flags microscopic vapor transmission down to 0.005 g\/m²·24h, providing fast, dependable lot certification for flat substrates alongside complete consumer containers.\u003c\/p\u003e\n\u003ch2\u003eStandards \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eASTM F1249:\u003c\/strong\u003e Standardized test method for water vapor transmission rates across plastic sheeting using an optical modulated infrared detector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 15106-2:\u003c\/strong\u003e International standard for plastics film and sheeting moisture vapor determination via infrared detection sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTAPPI T557:\u003c\/strong\u003e Regulated procedure for evaluating water vapor transmission through flexible barrier packaging sheets via modulated infrared sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJIS K 7129:\u003c\/strong\u003e Instrumental moisture permeation evaluation methods for plastic films and multi-layer barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimultaneous three-specimen capacity:\u003c\/strong\u003e Triples daily sample turnaround by testing three independent materials at once, cutting queue times during critical production sign-offs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical infrared detection:\u003c\/strong\u003e Identifies tiny quantities of moisture in the nitrogen sweep stream almost instantaneously, saving hours of waiting compared to traditional cup weighing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-level leakage sensitivity:\u003c\/strong\u003e Captures vapor penetration down to five-thousandths of a gram per square meter daily, giving you dependable readings on tough metal foil structures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual flat sheet and finished package flexibility:\u003c\/strong\u003e Tests raw rolls or attaches to modular fittings to assess formed pouches, trays, and bottles on the same device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCirculating bath thermal control:\u003c\/strong\u003e Keeps every chamber held at uniform temperatures from 5°C up to 95°C for repeatable temperature evaluations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividual chamber temperature monitoring:\u003c\/strong\u003e Houses dedicated heat sensors in each testing station, guaranteeing identical environmental exposures across all positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-command test cycles:\u003c\/strong\u003e Triggers the entire automated test run with a simple tap on the screen, minimizing operator training demands and setup variability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefensible calibration records:\u003c\/strong\u003e Synchronizes with certified standard barrier films to generate documented verification trails ready for external regulatory audits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInfrared Water Vapor Transmission Rate Tester (3-Cell) - ToronWVTR™ Ir3 Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"612\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilm Test Range (Standard)\u003c\/td\u003e\n\u003ctd\u003e0.005 to 42 g\/m²·24h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilm Test Range (Optional)\u003c\/td\u003e\n\u003ctd\u003e0.05 to 1,000 g\/m²·24h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilm Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 g\/m²·24h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Test Range\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 0.3 g\/pkg·d (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Resolution\u003c\/td\u003e\n\u003ctd\u003e0.00001 g\/pkg·d\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen Amount\u003c\/td\u003e\n\u003ctd\u003e3, independent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e5°C to 95°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e0% RH; 35% to 90% RH; 100% RH (standard condition 90% RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Area\u003c\/td\u003e\n\u003ctd\u003e50 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen Size (Film)\u003c\/td\u003e\n\u003ctd\u003e≥ 150 mm × 94 mm; thickness \u0026lt; 3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen Size (Package)\u003c\/td\u003e\n\u003ctd\u003eMax Ø120 mm × 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Gas\u003c\/td\u003e\n\u003ctd\u003e99.999% Nitrogen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Flow\u003c\/td\u003e\n\u003ctd\u003e0 to 200 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Interface\u003c\/td\u003e\n\u003ctd\u003e1\/8 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eAC 220 V, 50 Hz (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e730 mm (L) × 590 mm (W) × 350 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandard Delivery\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"488\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Unit\u003c\/td\u003e\n\u003ctd\u003eThree-chamber infrared WVTR test instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputer\u003c\/td\u003e\n\u003ctd\u003eDedicated control PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Software\u003c\/td\u003e\n\u003ctd\u003eInstrument operation and data-analysis software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Controller\u003c\/td\u003e\n\u003ctd\u003eWater-bath temperature control unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank Regulator\u003c\/td\u003e\n\u003ctd\u003eRegulates carrier gas supply pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCIe Acquisition Card\u003c\/td\u003e\n\u003ctd\u003eData acquisition interface for the control PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003eConnects the instrument to the control PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Cutter\u003c\/td\u003e\n\u003ctd\u003ePrepares specimens to the required test size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Grease\u003c\/td\u003e\n\u003ctd\u003eSeals the specimen at the chamber interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"612\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Fixtures\u003c\/td\u003e\n\u003ctd\u003eAdapters for testing finished packages such as pouches and bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Film\u003c\/td\u003e\n\u003ctd\u003eCertified film for traceable calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Grease\u003c\/td\u003e\n\u003ctd\u003eAdditional sealing grease for specimen mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Cutter\u003c\/td\u003e\n\u003ctd\u003eAdditional specimen-preparation cutter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Data Management System\u003c\/td\u003e\n\u003ctd\u003eCentralized data management and reporting software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":50733797802223,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/infrared-water-vapor-transmission-rate-tester-3-cell2108896250.webp?v=1789105980","url":"https:\/\/shop.torontech.com\/products\/3-cell-infrared-wvtr-tester-toronwvtr-ir3","provider":"Torontech","version":"1.0","type":"link"}