{"product_id":"transfer-stretcher-electric-toroncare-1180-e","title":"Transfer Stretcher (Electric) — ToronCare™ 1180 E","description":"\u003ch2\u003eElectric Transfer Stretcher\u003c\/h2\u003e\n\u003cp\u003eThe ToronCare™ 1180 E is a fully electric transfer stretcher designed for demanding hospital and acute care environments. Combining electric motor-driven adjustments with gas-spring-assisted positioning, this electric hospital stretcher provides efficient, one-touch control across multiple positioning functions, including height, backrest, knee gatch, Trendelenburg, reverse Trendelenburg, and chair position. Its integrated positioning system supports fast and controlled patient handling in high-acuity and high-throughput clinical settings across the U.S. and Canada.\u003c\/p\u003e\n\u003cp\u003eThe stretcher combines electric motors and gas springs to support its primary adjustment functions. The backrest and knee gatch are adjusted using gas-spring mechanisms, while height and Trendelenburg\/reverse Trendelenburg positioning are electrically controlled. Foot pedals positioned at both the head and foot ends provide secondary access to height and tilt adjustments, supporting continuous operation during demanding clinical workflows. Four corner bumpers help protect the stretcher and surrounding surfaces during transportation through confined hospital corridors. End-mounted push handles also support two-caregiver-assisted transport when maneuvering through narrow spaces.\u003c\/p\u003e\n\u003cp\u003eA radiolucent bed board allows X-ray imaging to be performed directly on the stretcher, reducing the need to reposition or transfer the patient during emergency and trauma procedures. Foldable side rails provide patient support during medical stretcher transport while allowing rapid access for clinical care. Central-lockable 360° swivel castors, measuring 200 mm in diameter, provide controlled mobility, while the retractable fifth directional wheel improves directional stability and maneuverability.\u003c\/p\u003e\n\u003cp\u003eAn optional weighing scale accessory enables patient weight monitoring without requiring a separate transfer. With a weight of 140 kg, the ToronCare™ 1180 E combines electric positioning, radiolucent imaging capability, mobility features, and patient-handling functions in a comprehensive electric hospital stretcher platform for U.S. and Canadian acute care facilities.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe ToronCare™ 1180 E electric transfer stretcher is designed for a range of acute care, emergency, diagnostic, and surgical applications where powered patient positioning and efficient transport are essential.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLevel I Trauma Centers and Emergency Departments: Supports rapid, one-touch patient positioning and transport during emergency care and trauma workflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eICU and Critical Care: Suitable for high-acuity patient transport where powered positioning can reduce the physical effort required from caregivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRadiology and Interventional Suites: The radiolucent bed board supports X-ray imaging directly on the stretcher, reducing the need for patient transfers during diagnostic and interventional procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBariatric Patient Care: Provides powered positioning and transport capabilities for situations where manual stretcher adjustment may present additional handling challenges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSurgical Suites: Supports chair position, knee gatch, Trendelenburg, and reverse Trendelenburg adjustments for procedures requiring multiple patient positions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIn-Place Patient Weight Monitoring: The optional weighing scale allows patient weight measurements directly on the stretcher without requiring a separate weighing transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAcute Care Facilities: Suitable for hospitals seeking a fully electric stretcher platform that can support patient transport and positioning across multiple departments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/toroncaretm-1180-e-1429992848.webp?v=1790404122\" alt=\"Transfer Stretcher (Electric) — ToronCare™ 1180 E\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFully Electric Drive: Motor-driven height adjustment and Trendelenburg\/reverse Trendelenburg positioning with one-touch operation through foot pedals located at both the head and foot sides.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas-Spring Backrest and Knee Gatch: Backrest adjustment from 0° to 70° and knee gatch adjustment from 0° to 40° provide fast, low-force positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChair Position: Coordinated backrest and knee gatch movement creates a seated patient posture directly on the stretcher without requiring patient transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrendelenburg\/Reverse Trendelenburg: Electric tilt adjustment from 0° to 12° supports a range of clinical positioning requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeight Adjustment: Bed board height ranges from 790 to 565 mm above the ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRadiolucent Bed Board: Supports full-body X-ray imaging directly on the stretcher, reducing the need for patient transfer during diagnostic procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFoldable Side Rails: Provide patient support during stretcher transport while allowing rapid lowering for clinical access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated Push Handles and IV Pole Holders: Foot-end push handles assist with stretcher transport and also function as IV pole holders for convenient infusion management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour Corner Bumpers: Help protect the stretcher frame and surrounding walls during transportation through confined hospital corridors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentral-Lockable 360° Swivel Castors: 200 mm diameter castors with brake pedals positioned at both the head and foot sides provide controlled mobility and secure positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetractable Fifth Directional Wheel: Improves straight-line steering and directional control when maneuvering through hospital corridors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional Weighing Scale: Enables patient weight monitoring directly on the stretcher without requiring a separate transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNet Weight: 140 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard Accessories: Includes 2 × IV poles, each equipped with 2 foldable hooks; the poles can also be used as push handles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eThe ToronCare™ 1180 E combines electric motor drives with gas-spring mechanisms to provide controlled movement across its patient-positioning functions. Electric motors control height adjustment from 790 to 565 mm (bed board to ground) and Trendelenburg\/reverse Trendelenburg positioning from 0° to 12°, allowing consistent positioning through electronic controls. The backrest adjusts from 0° to 70°, while the knee gatch adjusts from 0° to 40° using gas-spring mechanisms for fast, low-force articulation with minimal caregiver effort.\u003c\/p\u003e\n\u003cp\u003eThe chair-position function coordinates movement of the backrest and knee gatch to create a semi-seated patient position directly on the stretcher. This allows patients to sit upright for examination, recovery, or oral intake without moving to a separate chair or seating surface. Keeping these activities on the stretcher can reduce the number of patient transfers required during a clinical episode.\u003c\/p\u003e\n\u003cp\u003eThe foot-end push handles, which also serve as IV pole holders, provide secure handling points for two caregivers during stretcher transportation through corridors, ramps, and elevator areas. Brake pedals positioned at both the head and foot sides allow the 200 mm swivel castors to be locked for secure positioning regardless of stretcher height or patient position. A retractable fifth directional wheel supports improved straight-line tracking and directional control during longer-distance hospital stretcher transport.\u003c\/p\u003e\n\u003ch2\u003eTransfer Stretcher (Electric) — ToronCare™ 1180 E Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eToronCare™ 1180 E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eElectric Transfer Stretcher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Dimension\u003c\/td\u003e\n\u003ctd\u003e2175 × 785 mm (L × W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight Range (Bed Board to Ground)\u003c\/td\u003e\n\u003ctd\u003e790 – 565 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBed Board Dimension\u003c\/td\u003e\n\u003ctd\u003e1990 × 630 mm (L × W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackrest Angle\u003c\/td\u003e\n\u003ctd\u003e0° – 70° (gas-spring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnee Gatch\u003c\/td\u003e\n\u003ctd\u003e0° – 40°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrendelenburg \/ Rev. Trendelenburg\u003c\/td\u003e\n\u003ctd\u003e0° – 12° (electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChair Position\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight Adjustment\u003c\/td\u003e\n\u003ctd\u003eElectric motor, foot-pedal (head and foot sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Rails\u003c\/td\u003e\n\u003ctd\u003eFoldable stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBed Board\u003c\/td\u003e\n\u003ctd\u003eRadiolucent — X-ray imaging capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorner Bumpers\u003c\/td\u003e\n\u003ctd\u003e4× corner bumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCastor Diameter\u003c\/td\u003e\n\u003ctd\u003e200 mm, central-lockable 360° swivel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5th Wheel\u003c\/td\u003e\n\u003ctd\u003eRetractable, directional control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePush Handles \/ IV Poles\u003c\/td\u003e\n\u003ctd\u003e2 × IV poles (2 foldable hooks each), double as push handles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessory\u003c\/td\u003e\n\u003ctd\u003eWeighing scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e140 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":50896020537583,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/transfer-stretcher-electric-toro_1.webp?v=1790404170","url":"https:\/\/shop.torontech.com\/fr\/products\/transfer-stretcher-electric-toroncare-1180-e","provider":"Torontech","version":"1.0","type":"link"}