{"product_id":"transfer-stretcher-advanced-toroncare-1140-a","title":"Transfer Stretcher (Advanced) — ToronCare™ 1140 A","description":"\u003ch2\u003eManual Transfer Stretcher\u003c\/h2\u003e\n\u003cp\u003eThe ToronCare™ 1140 A is an advanced manual transfer stretcher designed to build on the established ToronCare™ 1140 platform. It features enhanced backrest articulation indicators and gas-spring-controlled retractable PP side railings, providing a practical hospital stretcher bed for healthcare facilities that require accurate patient positioning and efficient lateral transfer.\u003c\/p\u003e\n\u003cp\u003eA key feature of the ToronCare™ 1140 A manual transfer stretcher is its integrated backrest angle indicator system. Positioned beneath both sides of the backrest section, the indicators provide a clear reference for the backrest elevation angle, helping clinical staff achieve consistent patient positioning during transport to operating rooms, imaging departments, and procedure areas. This positioning control can be particularly useful when managing patients who require specific respiratory, spinal, or post-operative positioning.\u003c\/p\u003e\n\u003cp\u003eThe damping PP retractable side railings use gas-spring control for smooth and controlled movement. The railings can be lowered and retracted beneath the bed board surface, creating a flush transfer interface with adjacent operating tables or hospital beds. This configuration supports smooth lateral patient transfer across connected surfaces without requiring manual lifting.\u003c\/p\u003e\n\u003cp\u003eWith a net weight of 75 kg, the ToronCare™ 1140 A provides a functional medical stretcher transport solution for general wards, emergency departments, operating areas, and other healthcare environments across the United States and Canada.\u003c\/p\u003e\n\u003ch2\u003eTransfer Stretcher (Advanced) — ToronCare™ 1140 A\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eClinical environments requiring precise and consistent patient positioning during stretcher transportation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRespiratory, cardiac, and post-surgical patient transport where backrest angle monitoring and adjustment are important\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating room transfers requiring flush-contact, gap-free lateral movement between the stretcher and O.R. table\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency departments requiring a hospital emergency stretcher with quick, one-operator side-rail adjustment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHospitals and ambulatory care centers seeking ergonomic manual stretcher performance with enhanced positioning features\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeurology, spine, and orthopedic units where controlled backrest positioning supports patient transport requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHealthcare facilities upgrading their hospital stretcher and patient transport equipment with ergonomic, precision-positioning designs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTransfer Stretcher (Advanced) — ToronCare™ 1140 A Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/toroncaretm-1140-869207878.webp?v=1790404793\" alt=\"Transfer Stretcher (Advanced) — ToronCare™ 1140 A\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDual backrest angle indicators positioned beneath both sides of the backrest provide clear, visual angle references for accurate patient positioning during stretcher transport\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas-spring-controlled damping PP retractable side railings allow smooth, controlled retraction beneath the bed board, supporting seamless docking with adjacent patient surfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap-free transfer interface with an operating table or hospital bed supports direct lateral patient transfer without lifting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManual scissor-lift crank height adjustment provides a 860–505 mm height range, measured from the bed board to the ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackrest adjustment from 0° to 85° with bilateral angle indicators supports consistent positioning during patient care and transportation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentral-lockable 360° swivel castors, 150 mm in diameter, allow simultaneous locking of all wheels for stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetractable 5th wheel provides enhanced directional control and maneuverability during stretcher transportation through hospital corridors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge bed board, measuring 1903 × 650 mm, provides a spacious patient support surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e75 kg net weight supports frequent handling and routine patient transport across hospital departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard accessories include a mattress and IV pole\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eThe ToronCare™ 1140 A uses a manual crank-driven scissor-lift mechanism to adjust stretcher height from 860 to 505 mm, measured from the bed board to the ground. The crank system provides controlled, stepless height adjustment across the full operating range, supporting stable patient positioning throughout transport and transfer procedures.\u003c\/p\u003e\n\u003cp\u003eThe bilateral backrest angle indicator system uses graduated scales positioned beneath the backrest articulation points. As the backrest moves between raised and lowered positions, an indicator pointer follows the corresponding angle on the scale, providing a direct visual reference for positioning. This allows clinical staff to set and verify backrest angles without relying on visual estimation or a separate angle-measuring device.\u003c\/p\u003e\n\u003cp\u003eThe gas-spring-controlled PP retractable side railings provide smooth, damped movement during retraction beneath the bed board. The controlled spring action helps minimize sudden movement and impact as the railings are lowered. Once retracted, the railings sit flush beneath the bed board, allowing the ToronCare™ 1140 A to align closely with an operating table or hospital bed for gap-free lateral patient transfer. After release, the gas-spring mechanism guides the side railings back toward their upright safety position.\u003c\/p\u003e\n\u003ch2\u003eTransfer Stretcher (Advanced) — ToronCare™ 1140 A Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eToronCare™ 1140 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eManual Transfer Stretcher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Dimension\u003c\/td\u003e\n\u003ctd\u003e2067 × 713 mm (L × W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight Range (Bed Board to Ground)\u003c\/td\u003e\n\u003ctd\u003e860 – 505 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBed Board Dimension\u003c\/td\u003e\n\u003ctd\u003e1903 × 650 mm (L × W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackrest Angle\u003c\/td\u003e\n\u003ctd\u003e0° – 85°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackrest Angle Indicators\u003c\/td\u003e\n\u003ctd\u003eFixed bilateral angle display under backrest section\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCastor Diameter\u003c\/td\u003e\n\u003ctd\u003e150 mm, central-lockable 360° swivel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5th Wheel\u003c\/td\u003e\n\u003ctd\u003eRetractable, directional control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Rails\u003c\/td\u003e\n\u003ctd\u003eDamping PP, gas-spring controlled, retractable under bed board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight Adjustment\u003c\/td\u003e\n\u003ctd\u003eManual crank, scissor-lift frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd\u003eMattress, IV pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":50896084173039,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/transfer-stretcher-advanced-toro.webp?v=1790404900","url":"https:\/\/shop.torontech.com\/fr\/products\/transfer-stretcher-advanced-toroncare-1140-a","provider":"Torontech","version":"1.0","type":"link"}