{"product_id":"6-cell-gas-permeability-tester-torongpt-6a","title":"6-Cell Gas Permeability Tester - ToronGPT™ 6A","description":"\u003cp\u003eThe ToronGPT™ 6A cuts processing bottlenecks across high-volume inspection labs by running six barrier film specimens side by side.\u003c\/p\u003e\n\u003cp\u003eUsing differential vacuum pressure principles adhering to ASTM D1434 and ISO 15105-1 benchmarks, this automated six-port instrument runs from chamber evacuation through file saving without requiring ongoing technician supervision. It supplies exact gas transmission rates, diffusion values, and solubility coefficients down to 0.01 cm³\/(m²·24h·0.1MPa), keeping large product release schedules running without delays.\u003c\/p\u003e\n\u003ch2\u003eStandards \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eASTM D1434:\u003c\/strong\u003e Standard test method for determining gas permeability characteristics of plastic film and flexible sheeting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 15105-1:\u003c\/strong\u003e International testing specification for evaluating plastics film and sheeting gas transmission rates via differential-pressure methods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 2556:\u003c\/strong\u003e Standard manometric method for determining the gas transmission rate of films and thin sheets under atmospheric pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJIS K 7126-1:\u003c\/strong\u003e Japanese industrial test methodology for verifying gas transmission rates through plastic sheeting using differential pressure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix-station simultaneous testing:\u003c\/strong\u003e Evaluates six independent test specimens at once, doubling analytical throughput for operations handling big sample queues each shift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-touch automated sequencing:\u003c\/strong\u003e Executes evacuation, gas feeding, and file recording automatically from a single click, cutting down on technician training and setup variance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverlaid visual curve analysis:\u003c\/strong\u003e Plots transmission progress, chamber warmth, and pressure curves for all six cells onto one display, making it easy to identify batch variations immediately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent barrier detection:\u003c\/strong\u003e Adjusts measurement parameters automatically to match the density of each specimen, delivering accurate readings across common wraps and heavy foils alike.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad permeation range:\u003c\/strong\u003e Captures gas transmission rates starting at 0.01 and reaching 190,000 cm³\/(m²·24h·0.1MPa) on the same testing instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFine-scale vacuum resolution:\u003c\/strong\u003e Features internal vacuum sensors reading pressure variations down to 0.1 Pa to produce stable calculations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCirculating liquid-bath thermal regulation:\u003c\/strong\u003e Holds internal test conditions steady between 5°C and 95°C for repeatable isothermal evaluations over long weekends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsolidated laboratory record-keeping:\u003c\/strong\u003e Connects directly to central quality software networks for automated data exports, regulatory compliance, and report generation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAutomatic 6-Cell Gas Permeability Tester - ToronGPT™ 6A Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"867\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.01 to 190,000 cm³\/(m²·24h·0.1MPa) (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 cm³\/(m²·24h·0.1MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Chambers\u003c\/td\u003e\n\u003ctd\u003e6, independent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e5°C to 95°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e0% RH; 35% to 90% RH; 100% RH (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% RH (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Thickness\u003c\/td\u003e\n\u003ctd\u003e≤ 3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Size\u003c\/td\u003e\n\u003ctd\u003e≥ 150 mm × 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Area\u003c\/td\u003e\n\u003ctd\u003e48 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Gases\u003c\/td\u003e\n\u003ctd\u003eO₂, N₂, CO₂, He, and others (user-supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Pressure\u003c\/td\u003e\n\u003ctd\u003e-0.1 MPa to 0.1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Interface\u003c\/td\u003e\n\u003ctd\u003eØ8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e650 mm (L) × 700 mm (W) × 420 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eAC 220 V, 50 Hz (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandard Delivery\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"873\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Unit\u003c\/td\u003e\n\u003ctd\u003eSix-chamber gas permeability test instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputer\u003c\/td\u003e\n\u003ctd\u003eDedicated control PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Software\u003c\/td\u003e\n\u003ctd\u003eInstrument operation and data-analysis software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Controller\u003c\/td\u003e\n\u003ctd\u003eWater-bath temperature control unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003eEvacuates the gas circuit before testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank Regulator\u003c\/td\u003e\n\u003ctd\u003eRegulates supply pressure from the test-gas cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCIe Acquisition Card\u003c\/td\u003e\n\u003ctd\u003eData acquisition interface for the control PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003eConnects the instrument to the control PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Cutter\u003c\/td\u003e\n\u003ctd\u003ePrepares specimens to the required test size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Grease\u003c\/td\u003e\n\u003ctd\u003eSeals the specimen at the chamber interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"868\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Generator\u003c\/td\u003e\n\u003ctd\u003eAdds controlled relative-humidity testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Film\u003c\/td\u003e\n\u003ctd\u003eCertified film for traceable calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Grease\u003c\/td\u003e\n\u003ctd\u003eAdditional sealing grease for specimen mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Cutter\u003c\/td\u003e\n\u003ctd\u003eAdditional specimen-preparation cutter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Data Management System\u003c\/td\u003e\n\u003ctd\u003eCentralized data management and reporting software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":50733986480367,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/automatic-6-cell-gas-permeability-tester22506515.webp?v=1789109923","url":"https:\/\/shop.torontech.com\/es\/products\/6-cell-gas-permeability-tester-torongpt-6a","provider":"Torontech","version":"1.0","type":"link"}