{"title":"Pour Point and Cloud Point Testing","description":"\u003cp class=\"ng-star-inserted\"\u003e\u003cspan class=\"ng-star-inserted\"\u003eOur lineup of Pour Point and Cloud Point Testing instruments helps petroleum refineries and fuel laboratories evaluate cold-temperature fluid behavior. These units measure the exact temperature where wax crystals begin forming as well as the point where liquid flow ceases, adhering to recognized standards like ASTM D97 and ASTM D2500.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003cspan class=\"ng-star-inserted\"\u003eWith options spanning traditional metal bath apparatus to fully automated units featuring optical wax detection, this pour point and cloud point testing selection fits diverse operational budgets and sample volumes. Integrating these testing systems into your quality control setup ensures cold-weather fuel operability and consistent specification verification.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"automatic-pour-cloud-point-tester-tt-9725","title":"Automatic Pour \u0026 Cloud Point Tester TT-9725","description":"\u003cp\u003eThe TT-9725 automated testing unit evaluates critical cold flow behavior in petroleum fuels and lubricants without needing extra cooling hardware. This standalone device handles sample cooling down to -80°C to pinpoint wax crystal formation and fluid flow limits within a single operational cycle.\u003c\/p\u003e\n\u003cp\u003eBuilt specifically for refinery quality control setups, commercial fuel facilities, and independent analytical laboratories, it keeps testing simple while meeting global industry specifications including ASTM D97, ASTM D2500, ISO 3015, and ISO 3016.\u003c\/p\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-in-One Chilling Setup:\u003c\/strong\u003e Drops test temperatures to -80°C using an internal cooling assembly, saving bench space and removing the hassle of liquid chillers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual CP and PP Analysis:\u003c\/strong\u003e Runs cloud point and pour point evaluations simultaneously in one automated sequence to accelerate laboratory workflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated Sample Handling:\u003c\/strong\u003e Lifts and rotates test vials automatically to guarantee consistent measurement routines with zero manual handling errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Precision Temperature Tracking:\u003c\/strong\u003e Uses a Pt-100 thermal sensor alongside optical detection tools to deliver 0.1°C resolution across all sample runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Heating System:\u003c\/strong\u003e Features an internal heating element to restore optimal bath conditions swiftly between consecutive test cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntuitive Touch Interface:\u003c\/strong\u003e Offers a spacious color LCD screen that allows technicians to manage runs, view live data, and adjust settings effortlessly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless LIMS \u0026amp; Network Integration:\u003c\/strong\u003e Equipped with LAN ports, USB slots, and 8GB of internal storage to connect with laboratory networks and export detailed records.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Operational Footprint:\u003c\/strong\u003e Combines an energy-efficient 500W draw with a compact frame (500 x 440 x 770 mm) to fit easily into crowded lab spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"accordion-button icon-link icon-link-hover\" id=\"accordion-field-technical-specifications\" role=\"button\"\u003eTechnical Specifications of Automatic Pour \u0026amp; Cloud Point Tester TT-9725\u003c\/h2\u003e\n\u003ch2 class=\"accordion-header\" id=\"heading_field_technical_specifications\"\u003e\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%; font-family: Arial, sans-serif;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2; text-align: left;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-80~51℃, ±0.1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated cooling system without external chiller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB, LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220V±10%, 50Hz (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500*440*770mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":50322353684719,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/fully-automatic-pour-and-cloud-point-tester1506155916.webp?v=1785922248"},{"product_id":"metal-bath-pour-cloud-point-tester-tt-97j","title":"Metal Bath Pour \u0026 Cloud Point Tester TT-97J","description":"\u003cp\u003eThe TT-97J testing system measures low-temperature fluid behavior in petroleum products, engine oils, and hydraulic fluids without relying on messy liquid baths.\u003c\/p\u003e\n\u003cp\u003eUtilizing solid metal block refrigeration, this benchtop unit cools samples down to -70°C to determine exact cloud point and pour point metrics according to ASTM D97 and ASTM D2500 standards. It provides fuel refineries, lubricant production facilities, and heavy equipment testing sites with a clean, low-maintenance solution to verify cold weather performance and prevent equipment fuel gelation.\u003c\/p\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid-Free Metal Bath Cooling:\u003c\/strong\u003e Uses direct metal block contact to reach freezing temperatures, eliminating messy liquid cooling fluids and reducing overall maintenance demands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Temperature Stations:\u003c\/strong\u003e Features two separate test bays capable of running different temperature profiles simultaneously for improved lab productivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Danfoss Refrigeration:\u003c\/strong\u003e Driven by a Danfoss compound compressor system that achieves swift cooling down to -70°C with steady temperature holding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePID Digital Control:\u003c\/strong\u003e Built with an easy-to-read digital panel paired with PID thermal management to maintain accurate temperature control within ±0.2°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Benchtop Frame:\u003c\/strong\u003e Fits conveniently onto standard laboratory benches while consuming under 1500W during full operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance Ready:\u003c\/strong\u003e Fully conforms to ASTM D97 and ASTM D2500 protocols to ensure accepted quality control documentation across global supply chains.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications of Metal Bath Pour \u0026amp; Cloud Point Tester TT-97J\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%; font-family: Arial, sans-serif;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2; text-align: left;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC220V±10%, 50Hz (110V also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEquipped with double test stations featuring different temperature settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-70°C to ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUtilizes Danfoss compound compressor cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal power consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":50322424135919,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/metal-bath-pour-and-cloud-point-tester1316030538.webp?v=1785922728"},{"product_id":"torondacs-200-data-calculation-system","title":"ToronDACS™ 200 Data \u0026 Calculation System","description":"\u003cp\u003eThe ToronDACS™ 200 peripheral system automates weight capture and mathematical processing for carbon residue testing without needing a standalone personal computer.\u003c\/p\u003e\n\u003cp\u003eWorking alongside testing units such as the ToronCR™ 500, this compact unit pulls weight readings directly from connected analytical balances, calculates carbon residue percentages for up to twelve sample batches, and verifies repeatability against ASTM D4530 and ISO 10370 standards. It provides petroleum quality assurance labs and testing facilities with an automated workflow that eliminates manual entry mistakes and simplifies compliance reporting.\u003c\/p\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Balance Integration:\u003c\/strong\u003e Hooks up seamlessly to Sartorius, Mettler Toledo, and other RS-232 enabled analytical scales to collect mass measurements automatically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError-Free Calculations:\u003c\/strong\u003e Automatically computes carbon residue percentages across 1 to 12 sample groups, removing human calculation errors and saving operator time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Precision Verification:\u003c\/strong\u003e Checks test repeatability automatically against ASTM D4530 and ISO 10370 limits to confirm valid test outcomes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Board Thermal Printer:\u003c\/strong\u003e Outputs instant hard-copy test documentation directly from the main module without attaching external printing hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutage Memory Safeguard:\u003c\/strong\u003e Features non-volatile storage that protects logged sample data and calculations during unexpected electrical interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear Touchscreen Controls:\u003c\/strong\u003e Uses a 5.6-inch color display to make menu choices clear and operational adjustments straightforward for technicians.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpanded Storage Capacity:\u003c\/strong\u003e Retains up to 200 data groups internally to back up routine testing records before transferring to long-term archives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Measures just 220 x 180 x 130 mm while consuming under 10W of electrical energy, fitting effortlessly into crowded lab environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAutomated Data Acquisition and Calculation System – ToronDACS™ 200 Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalculation Capacity\u003c\/td\u003e\n\u003ctd\u003e1 – 12 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e200 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinting\u003c\/td\u003e\n\u003ctd\u003eAutomatic (integrated printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Protection\u003c\/td\u003e\n\u003ctd\u003ePower-off memory retention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e≤ 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen Display\u003c\/td\u003e\n\u003ctd\u003e5.6-inch 65K-color true-color configurable touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Unit Size (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e220 × 180 × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eAC 220 V ± 10%, 50 Hz ± 10% (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e20 – 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther Notes\u003c\/td\u003e\n\u003ctd\u003eNo strong vibration, airflow, strong electromagnetic interference, or corrosive gases near instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":50322450972911,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/automated-data-acquisition-and-calculation-system1346636926.webp?v=1785923122"},{"product_id":"pour-solidifying-point-tester-toronpp-psp-97","title":"Pour \u0026 Solidifying Point Tester ToronPP™ PSP 97","description":"\u003cp\u003eThe ToronPP™ PSP 97 automated testing station measures low-temperature behavior in lubricating base oils, heavy mineral products, and dark petroleum fractions.\u003c\/p\u003e\n\u003cp\u003eEquipped with two independent sample bays, this benchtop analyzer cools specimens down to -70°C while carrying out standard tilt maneuvers per ASTM D97 and ASTM D2386 requirements. It delivers dependable optical detection for busy lubricant manufacturing facilities and commercial testing labs looking to double sample output, maintain strict quality control records, and connect directly to internal LIMS networks.\u003c\/p\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Sample Capacity:\u003c\/strong\u003e Features two simultaneous test bays, allowing lab technicians to run two separate oil specimens at once to double operational throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Fiber Sensing:\u003c\/strong\u003e Uses automated photoelectric fiber optics to detect fluid movement limits without human bias or manual observation errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Thermal Range:\u003c\/strong\u003e Regulates sample temperatures smoothly from +50°C down to -70°C with 0.1°C resolution for comprehensive cold weather analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardized Tilt System:\u003c\/strong\u003e Executes automated tilt cycles matching ASTM D97 observation protocols to ensure fully compliant laboratory testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Touch Control Screen:\u003c\/strong\u003e Incorporates a 10-inch true-color display interface that makes setting up test profiles straightforward for operators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive LIMS Connectivity:\u003c\/strong\u003e Offers Ethernet, RS-232, and USB communication channels to transfer test logs straight to central lab management systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Compressor Assembly:\u003c\/strong\u003e Built with an industrial refrigeration system designed for extended service lifetimes and consistent cooling cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional CFPP Module:\u003c\/strong\u003e Supports an optional cold filter plugging point unit attachment for facilities wanting to expand overall testing options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePour Point \u0026amp; Solidifying Point Tester – ToronPP™ PSP 97 Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003eRoom temperature to -70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Positions\u003c\/td\u003e\n\u003ctd\u003e2 (can be measured simultaneously)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003ePhotoelectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003eFreezing point: ± 2 °C; Pour point: ± 3 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e10-inch True Color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Unit Size (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e800 × 650 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e80 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eAC 220 V ± 10%, 50 Hz ± 10% (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e5 – 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther Notes\u003c\/td\u003e\n\u003ctd\u003eNo strong vibration, airflow, strong electromagnetic interference, or corrosive gases near instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":50322503041263,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/pour-point-solidifying-point-tester1195805281.webp?v=1785923609"},{"product_id":"pour-freeze-cfpp-tester-toronpp-fpc-1000","title":"Pour, Freeze \u0026 CFPP Tester ToronPP™ FPC 1000","description":"\u003cp\u003eThe ToronPP™ FPC 1000 multi-function testing platform evaluates pour point, freezing point, and cold filter plugging point (CFPP) within one automated assembly. Built for diesel fuels, aviation turbine fuels, biodiesel blends, and lubricants, this analyzer cools samples down to -70°C using an integrated Peltier compressor setup.\u003c\/p\u003e\n\u003cp\u003eFeaturing dual detection bays and modular CFPP expansion, it equips fuel terminals, commercial refineries, and aviation supply chains with a flexible solution to fulfill ASTM D97, ASTM D2386, and EN 116 standards on a single benchtop setup.\u003c\/p\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-in-One Testing Capability:\u003c\/strong\u003e Combines pour point, freezing point, and cold filter plugging analysis into a single instrument to optimize lab bench space and equipment investments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Simultaneous Sample Bays:\u003c\/strong\u003e Runs two sample jars at the same time to accelerate sample throughput and improve laboratory testing capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable CFPP Module:\u003c\/strong\u003e Connects quickly to standard vacuum wire-mesh filter assemblies for straightforward distillate and biodiesel cold-flow certification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated Photoelectric Sensing:\u003c\/strong\u003e Employs optical fiber sensors to record precise fluid movement and filter pass limits without relying on visual operator checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Refrigeration System:\u003c\/strong\u003e Combines Peltier elements with compressor cooling to reach down to -70°C with 0.1°C resolution and ±1°C accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardized Tilt Sequence:\u003c\/strong\u003e Executes automatic tilt maneuvers strictly adhering to ASTM D97 and ASTM D2386 testing guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated LIMS Connectivity:\u003c\/strong\u003e Includes Ethernet, RS-232, and USB ports to send test reports straight into enterprise lab software systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Self-Checks:\u003c\/strong\u003e Features automated system monitoring with real-time operational alerts to keep equipment downtime to a minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePour Point, Freezing Point \u0026amp; Cold Filter Point Tester – ToronPP™ FPC 1000 Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003eRoom temperature to -70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Positions\u003c\/td\u003e\n\u003ctd\u003e2 (can be measured simultaneously)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003ePhotoelectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003eFreezing point: ± 2 °C; Pour point: ± 3 °C; Cold filter point: ± 1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e10-inch True Color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Unit Size (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e800 × 600 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e80 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFPP Unit\u003c\/td\u003e\n\u003ctd\u003eExpandable; simple and quick connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eAC 220 V ± 10%, 50 Hz ± 10% (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e10 – 28 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther Notes\u003c\/td\u003e\n\u003ctd\u003eNo strong vibration, airflow, strong electromagnetic interference, or corrosive gases near instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":50322510446831,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/pour-point-freezing-point-cold-filter-point-tester846276121.webp?v=1785924042"}],"url":"https:\/\/shop.torontech.com\/es\/collections\/pour-point-and-cloud-point-testing.oembed","provider":"Torontech","version":"1.0","type":"link"}