{"title":"Medical Waste Treatment","description":"\u003ch2\u003eMedical Waste Treatment Systems\u003c\/h2\u003e\n\u003ch4\u003eSteam-Based Medical Waste Treatment, Chemical-Free Processing Validated by Cycle Records\u003c\/h4\u003e\n\u003cp\u003eMedical waste treatment systems provide an effective solution for processing infectious waste from hospitals, laboratories, healthcare facilities, and clinical environments. Using saturated steam, these systems inactivate harmful microorganisms without chemical additives, combustion, or radiation. Treatment performance can be assessed against applicable STAATT inactivation criteria, while recorded temperature and pressure data support cycle monitoring, validation, and regulatory documentation.\u003c\/p\u003e\n\u003cp\u003eDesigned for hospitals, laboratories, medical waste contractors, and centralized treatment facilities, medical waste treatment equipment helps reduce the handling and transportation of untreated infectious waste. On-site or near-source treatment can minimize temporary storage requirements, reduce waste collection frequency, and lower the risks associated with transporting infectious materials on public roads.\u003c\/p\u003e\n\u003cp\u003eOur range of medical waste treatment systems accommodates different operational requirements, with processing capacities ranging from 100 L to 9,600 L per cycle. These solutions support efficient infectious waste management across healthcare facilities and specialized waste treatment operations.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eSteam-based medical waste treatment systems support healthcare facilities and waste management operations that require a reliable method of treating regulated infectious waste without incineration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHospitals and Medical Centers: Treat sharps, dressings, laboratory cultures, and isolation waste on-site, reducing the need to store untreated infectious materials between collections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentral Treatment Plants and Waste Contractors: Process medical waste collected from multiple facilities across a city or region, with system capacities suited to high-volume batch operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClinical and Diagnostic Laboratories: Treat culture plates, specimen containers, and biological materials before disposal, subject to applicable waste management requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePharmaceutical and Biotechnology Facilities: Process contaminated production consumables, filter media, and laboratory waste through documented treatment cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVeterinary and Animal Research Facilities: Treat contaminated bedding, animal tissues, and laboratory consumables requiring sterilization and, where necessary, size reduction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutpatient Clinics and Dialysis Centers: Process dialyzers, tubing, and contaminated disposable medical supplies using systems suited to smaller facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuarantine and Emergency Response Facilities: Manage regulated medical waste at ports, border stations, temporary medical facilities, and field hospitals where municipal waste infrastructure may be limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMedical Waste Treatment Systems\u003c\/h2\u003e\n\u003cp\u003eTorontech offers two medical waste treatment system configurations, designed for different processing volumes, loading methods, and waste handling requirements.\u003c\/p\u003e\n\u003ch3\u003eMedical Waste Autoclave with Shredder (ToronMW™ AS)\u003c\/h3\u003e\n\u003cp\u003eThe ToronMW™ AS integrates waste shredding and steam sterilization within a single automated system. Medical waste enters the upper chamber, passes through a twin-shaft shredder, and moves into the lower chamber for steam treatment at 134°C to 138°C. Integrated shredding increases waste exposure to steam and reduces the size and recognizability of treated materials.\u003c\/p\u003e\n\u003cp\u003eSeven models provide processing capacities from 100 L to 2,500 L per cycle, with a reported volume reduction of 60% to 80%. This configuration is suitable for healthcare facilities and waste treatment operations that require integrated size reduction and sterilization.\u003c\/p\u003e\n\u003ch3\u003eHigh-Vacuum Medical Waste Autoclave (ToronMW™ A)\u003c\/h3\u003e\n\u003cp\u003eThe ToronMW™ A is a horizontal, bin-loaded medical waste autoclave designed for high-volume batch processing. Its pre-vacuum system reaches -0.9 bar within five minutes, removing trapped air to support steam penetration throughout bagged waste loads. Automatic bin loading and unloading help streamline material handling, while an integrated deodorization tower treats process exhaust.\u003c\/p\u003e\n\u003cp\u003eFive configurations offer capacities from 800 L to 9,600 L per cycle, with a stated processing rate of up to 1,400 kg per hour. This system is suited to centralized medical waste treatment plants and facilities handling large quantities of collected infectious waste.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Medical Waste Treatment System\u003c\/h2\u003e\n\u003cp\u003eSelecting the appropriate medical waste treatment equipment depends on waste volume, site infrastructure, loading requirements, and applicable treatment regulations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFor on-site medical waste treatment: Consider the ToronMW™ AS, which combines shredding and steam sterilization in one integrated system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor centralized treatment plants: Consider the ToronMW™ A, with larger chamber capacities and automated bin handling for high-volume operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen waste size reduction is required: Choose a shredder-equipped configuration to reduce waste volume and make treated items less recognizable. Confirm that the resulting process meets applicable regulatory requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen processing waste collected from multiple facilities: A bin-loaded high-vacuum autoclave can simplify loading, unloading, and batch management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor facilities without an existing steam supply: Evaluate smaller shredder-equipped models with an integrated electric steam generator and water purification package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor installations requiring exhaust treatment: Consider a high-vacuum autoclave with a deodorization tower to manage process exhaust and help control odors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor densely packed or bagged waste: A high-vacuum system can help remove trapped air and improve steam penetration. Proper cycle validation remains essential to verify treatment effectiveness throughout the load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose Torontech for Medical Waste Treatment Equipment?\u003c\/h2\u003e\n\u003cp\u003eTorontech supplies industrial testing, measurement, and specialized equipment to laboratories and manufacturers across North America and international markets. Our medical waste treatment range supports different healthcare waste processing requirements, from smaller on-site installations to high-capacity centralized facilities.\u003c\/p\u003e\n\u003cp\u003eOur team can help assess processing capacity, loading methods, site utilities, and applicable treatment requirements to identify a suitable system configuration. Technical assistance is available to support equipment selection, installation planning, and ongoing operational needs.\u003c\/p\u003e\n\u003ch2\u003eRequest a Quote\u003c\/h2\u003e\n\u003cp\u003eShare your estimated daily medical waste volume, available site utilities, and applicable regulatory treatment requirements to help identify the right medical waste treatment system for your facility.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.torontech.com\/contact-us\/\"\u003eContact the Torontech team\u003c\/a\u003e for pricing, system specifications, layout drawings, and lead-time information.\u003c\/p\u003e","products":[{"product_id":"medical-waste-autoclave-with-shredder","title":"Medical Waste Autoclave with Shredder","description":"\u003ch2\u003eMedical Waste Autoclave with Shredder – ToronMW™ AS\u003c\/h2\u003e\n\u003ch4\u003eOn-Site Medical Waste Sterilization and Volume Reduction\u003c\/h4\u003e\n\u003cp\u003eThe ToronMW™ AS Medical Waste Autoclave with Shredder provides an integrated solution for treating infectious medical waste at the point of generation. Combining mechanical shredding with saturated steam sterilization in a sealed vessel, the system reduces regulated healthcare waste into unrecognizable, non-infectious material suitable for disposal through approved municipal waste channels. Designed for hospitals, clinics, laboratories, and centralized medical waste treatment facilities, the system processes waste through an upper shredding chamber before transferring it to a lower chamber for steam sterilization. The treated output is dry, unrecognizable, and non-infectious.\u003c\/p\u003e\n\u003cp\u003eAn automated treatment cycle integrates waste loading, shredding, steam sterilization, condensation, vacuum drying, and discharge, minimizing direct operator contact with untreated waste. The enclosed chamber design helps contain aerosols, odors, and condensate throughout the treatment process. With a volume reduction rate of 60–80%, the ToronMW™ AS can reduce waste storage requirements, collection frequency, and transportation costs while minimizing the risks associated with off-site transport of untreated infectious waste. Each cycle generates temperature and pressure records to support process monitoring and regulatory documentation.\u003c\/p\u003e\n\u003cp\u003eThe ToronMW™ AS series offers seven capacity options ranging from 100 L to 2,500 L per cycle, accommodating the waste treatment requirements of small healthcare facilities and large centralized processing plants. Smaller models feature an integrated electric steam generator and water purification system, making them suitable for facilities without a central steam supply. Higher-capacity models can connect to an existing plant steam system. The process operates without chemical sterilizing agents or radiation and is designed to avoid generating additional hazardous liquid or solid waste streams, providing a practical solution for on-site medical waste sterilization and volume reduction.\u003c\/p\u003e\n\u003ch2\u003eMedical Waste Autoclave with Shredder – ToronMW™ AS Applications\u003c\/h2\u003e\n\u003cp\u003eThe ToronMW™ AS Medical Waste Autoclave with Shredder is designed for healthcare facilities, laboratories, and waste treatment plants that require on-site infectious medical waste treatment through steam sterilization and mechanical size reduction. It provides an alternative to incineration-based treatment and can reduce reliance on transporting untreated medical waste to external facilities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHospitals and Medical Centers: Treat sharps, dressings, laboratory cultures, and isolation waste on site, reducing the need to store untreated infectious material between collections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutpatient Clinics and Dialysis Centers: Process contaminated dialyzers, tubing, and disposable medical supplies in a compact treatment area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClinical and Diagnostic Laboratories: Sterilize culture plates, specimen containers, and biological laboratory waste before disposal through approved waste management channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePharmaceutical and Biotechnology Facilities: Treat contaminated production consumables, filter media, and laboratory waste through documented sterilization cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentral Medical Waste Treatment Plants: Process medical waste collected from multiple facilities, with system capacities reaching 2,500 L per cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVeterinary Hospitals and Animal Research Facilities: Treat contaminated animal bedding, tissues, and disposable materials requiring sterilization and size reduction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBlood Banks and Plasma Collection Centers: Process expired blood collection materials, collection sets, and contaminated packaging according to applicable waste treatment requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong-Term Care and Isolation Facilities: Treat infectious waste on site, helping reduce the movement of untreated materials through occupied areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Hospitals and Emergency Response Units: Support medical waste treatment in temporary healthcare facilities where municipal waste infrastructure is limited or unavailable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStandards and Microbial Inactivation\u003c\/h2\u003e\n\u003cp\u003eMedical waste treatment systems are evaluated according to their demonstrated ability to inactivate microorganisms and meet applicable regulatory requirements. The ToronMW™ AS uses saturated steam sterilization, with treatment performance requiring validation against the relevant microbial inactivation criteria and local regulatory requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSTAATT Level IV: The State and Territorial Association on Alternative Treatment Technologies (STAATT) established microbial inactivation criteria for alternative medical waste treatment technologies. Level IV is commonly associated with a minimum 8-log₁₀ reduction in microbial population, subject to the applicable validation protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApproval of alternative medical waste treatment technologies depends on the requirements of the relevant state, provincial, or municipal authority. Validation procedures, biological indicators, documentation, and acceptance criteria may vary by jurisdiction. Before commissioning, facilities should arrange site-specific performance validation using biological indicators and protocols accepted by the applicable regulatory authority. Confirm the required treatment level and validation criteria with the regulator before claiming compliance.\u003c\/p\u003e\n\u003ch2\u003eMedical Waste Autoclave with Shredder – ToronMW™ AS Key Features\u003c\/h2\u003e\n\u003cp\u003eThe ToronMW™ AS Medical Waste Autoclave with Shredder integrates mechanical shredding, saturated steam sterilization, and automated cycle control in one enclosed treatment system. Its design supports efficient infectious medical waste processing, reduced waste volume, and controlled handling across healthcare and centralized waste treatment facilities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLow-Speed, High-Torque Twin-Shaft Shredder: Processes dense mixed medical waste, glass, and plastics through controlled cutting action designed to reduce the risk of stalling and excessive mechanical wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic Jam Detection and Reverse Operation: Detects excessive resistance and reverses the shredder drive to help clear blockages and restore material flow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnti-Bridging Push Feeder: Uses a positive feeding mechanism to move waste into the cutting chamber, helping prevent material buildup and interruptions associated with gravity-fed systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCorrosion-Resistant Pressure Vessel: Features vessel surfaces designed to withstand demanding operating conditions and exposure to condensate, supporting durability during repeated treatment cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated Shredding, Sterilization, and Drying: Performs waste size reduction, steam treatment, and drying within an enclosed vessel, minimizing transfers of untreated waste between separate machines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully Automatic Cycle Control: Coordinates the treatment sequence from loading through discharge, reducing routine operator involvement and supporting consistent process execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated Water Purification System: Conditions the water supply for steam generation, helping facilities operate without a separate water treatment installation where compatible with site requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote Monitoring and Fault Diagnosis: Provides access to cycle information and alarm conditions for operational monitoring, troubleshooting, and maintenance planning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosed Odor and Emission Management: Uses a sealed treatment design and controlled process handling to help limit the release of odors, aerosols, and steam during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReduced Secondary Waste Generation: Designed to minimize additional hazardous liquid and solid waste streams associated with the treatment process, subject to the installation's discharge and operating requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical-Free, Radiation-Free Treatment: Uses saturated steam as the sterilization medium, eliminating the need for chemical sterilizing agents or radiation-based treatment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e60–80% Waste Volume Reduction: Combines shredding and treatment to reduce waste volume, helping lower storage requirements, container usage, and collection frequency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy-Duty Construction: Designed for demanding operating schedules in healthcare facilities and medical waste treatment plants, with construction intended to support reliable long-term operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated Steam Generator for Compact Models: The 100 L and 200 L models include an electric steam generator, allowing operation at suitable sites without a central plant steam supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eThe ToronMW™ AS Medical Waste Autoclave with Shredder uses saturated steam sterilization to inactivate microorganisms through moist heat. When steam condenses on cooler waste surfaces, it releases latent heat that transfers energy into the material. This heat denatures essential microbial proteins and damages cellular structures and nucleic acids, helping destroy vegetative bacteria, fungi, viruses, mycobacteria, and bacterial spores when validated time and temperature conditions are achieved. Compared with dry-heat treatment, saturated steam provides efficient heat transfer and can achieve microbial inactivation at lower temperatures and shorter exposure times.\u003c\/p\u003e\n\u003cp\u003eSteam pressure and temperature are directly related under saturated conditions. Depending on the operating parameters, steam pressures in the range of 0.2–0.3 MPa can correspond to temperatures above the commonly used 121°C sterilization benchmark. Higher-temperature cycles, such as those operating around 134°C, can reduce the exposure time required for effective treatment when supported by appropriate process validation. Air removal is essential because trapped air reduces heat transfer and can prevent steam from reaching all waste surfaces. The system uses air evacuation and controlled steam treatment to support effective heat penetration throughout the load.\u003c\/p\u003e\n\u003cp\u003eIntegrated shredding before sterilization distinguishes the ToronMW™ AS from conventional medical waste autoclaves that treat intact waste loads. Waste bags and compacted materials can restrict steam penetration and create cold spots within the load. Mechanical shredding breaks the waste into smaller fragments, increases exposed surface area, and helps reduce trapped air pockets, supporting more uniform steam contact and heat distribution. Shredding also reduces waste volume and can render sharps and recognizable clinical items unidentifiable. Effective treatment must still be confirmed through validated operating cycles and appropriate biological indicators, while final disposal must follow the applicable local medical waste regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/additional-image-1558657966.webp?v=1791888240\" alt=\"Medical Waste Autoclave with Shredder\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMedical Waste Autoclave Treatment Cycle Sequence\u003c\/h3\u003e\n\u003cp\u003eThe ToronMW™ AS Medical Waste Autoclave with Shredder integrates waste loading, mechanical size reduction, steam sterilization, condensation, vacuum drying, and discharge into an automated treatment sequence.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLoading: Medical waste enters the upper chamber, and the vessel closes to establish an enclosed treatment environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShredding: A push-feeding mechanism directs waste into the twin-shaft shredder, which reduces it into smaller fragments that fall into the lower chamber. Automatic jam detection and reverse operation help clear obstructions and maintain material flow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam Sterilization: Saturated steam enters the treatment chamber to expose the shredded waste to controlled temperature and pressure conditions. Operating parameters, such as temperatures of 134–138°C and pressures of 0.2–0.3 MPa, must be confirmed against the model specifications and validated treatment cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondensation: Residual steam condenses as the treatment phase ends, helping reduce excess moisture and prepare the load for subsequent drying.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVacuum Drying: A vacuum system removes residual vapor and moisture, helping produce a dry treated output while reducing residual odors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDischarging: Once the cycle reaches its specified completion and safety conditions, the discharge door opens for removal of the treated material. Final waste classification and disposal must comply with applicable local regulations and validated treatment requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMedical Waste Autoclave with Shredder - ToronMW™ AS Technical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ch3\u003eProcess Performance\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"547\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilization Temperature\u003c\/td\u003e\n\u003ctd\u003e134°C to 138°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilization Pressure\u003c\/td\u003e\n\u003ctd\u003e0.2 to 0.3 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicrobial Inactivation\u003c\/td\u003e\n\u003ctd\u003eSTAATT Level IV, ≥ 8 Log₁₀\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume Reduction\u003c\/td\u003e\n\u003ctd\u003e60% to 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment Agent\u003c\/td\u003e\n\u003ctd\u003eSaturated steam (chemical-free, radiation-free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShredder Type\u003c\/td\u003e\n\u003ctd\u003eTwin-shaft, low speed, high torque, auto-reversing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Stages\u003c\/td\u003e\n\u003ctd\u003eLoad, shred, sterilize, condense, vacuum, discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eFully automatic, remote monitoring and fault diagnosis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Range\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"854\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eToronMW™ AS-100\u003c\/th\u003e\n\u003cth\u003eToronMW™ AS-200\u003c\/th\u003e\n\u003cth\u003eToronMW™ AS-300\u003c\/th\u003e\n\u003cth\u003eToronMW™ AS-500\u003c\/th\u003e\n\u003cth\u003eToronMW™ AS-750\u003c\/th\u003e\n\u003cth\u003eToronMW™ AS-1000\u003c\/th\u003e\n\u003cth\u003eToronMW™ AS-2500\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment Capacity (L\/cycle)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003ctd\u003e2,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle Time* (min)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposal Weight** (kg\/h)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions L×W×H (m)\u003c\/td\u003e\n\u003ctd\u003e3.0 × 1.6 × 2.1\u003c\/td\u003e\n\u003ctd\u003e3.3 × 1.7 × 2.2\u003c\/td\u003e\n\u003ctd\u003e3.9 × 3.1 × 3.1\u003c\/td\u003e\n\u003ctd\u003e4.6 × 3.0 × 3.9\u003c\/td\u003e\n\u003ctd\u003e5.0 × 3.0 × 4.6\u003c\/td\u003e\n\u003ctd\u003e5.0 × 5.0 × 5.7\u003c\/td\u003e\n\u003ctd\u003e6.8 × 5.3 × 7.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (ton)\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003ctd\u003e4.3\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003ctd\u003eAvailable on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power*** (kW)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e* Cycle time varies with sterilization temperature and local regulatory requirements.\u003c\/p\u003e\n\u003cp\u003e** Disposal weight is calculated at a waste density of 0.1 kg\/L. Actual density varies with waste composition and local segregation practice.\u003c\/p\u003e\n\u003cp\u003e*** The AS-100 and AS-200 include an electric steam generator and water purification system, which accounts for their higher rated power. Larger models draw steam from the plant supply.\u003c\/p\u003e\n\u003ch3\u003eStandard Configuration\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"610\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Vessel\u003c\/td\u003e\n\u003ctd\u003eDual-chamber design with corrosion-resistant in-wall self-cleaning surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShredding Unit\u003c\/td\u003e\n\u003ctd\u003eBuilt-in twin-shaft shredder with auto-reversing drive and push feeder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteam Supply\u003c\/td\u003e\n\u003ctd\u003eElectric steam generator on AS-100 and AS-200; plant steam connection on AS-300 and above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment\u003c\/td\u003e\n\u003ctd\u003eIntegrated water purification system, no external softening required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum System\u003c\/td\u003e\n\u003ctd\u003eVacuum pump for pre-sterilization air removal and post-cycle drying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eAutomatic PLC cycle control with operator interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Support\u003c\/td\u003e\n\u003ctd\u003eRemote monitoring and fault diagnosis interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumentation\u003c\/td\u003e\n\u003ctd\u003eCycle temperature and pressure records for regulatory reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":51032961810671,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/medical-waste-autoclave-shredder_1.webp?v=1791888304"},{"product_id":"high-vacuum-medical-waste-autoclave","title":"High-Vacuum Medical Waste Autoclave","description":"\u003ch2\u003eHigh-Vacuum Medical Waste Autoclave – ToronMW™ A\u003c\/h2\u003e\n\u003ch4\u003eIndustrial Medical Waste Sterilization for Central Treatment Plants\u003c\/h4\u003e\n\u003cp\u003eThe ToronMW™ A High-Vacuum Medical Waste Autoclave provides high-capacity steam sterilization for bagged and binned infectious medical waste at regional treatment facilities and industrial waste management plants. Its single-stage pre-vacuum system reduces chamber pressure to -0.9 bar within five minutes, removing trapped air before steam enters the chamber to support effective heat penetration throughout the waste load. Five configurations offer treatment capacities from 800 L to 9,600 L per cycle, with maximum throughput reaching 1,400 kg per hour on the largest model.\u003c\/p\u003e\n\u003cp\u003eAutomated bin loading and unloading allow wheeled containers to move through the treatment process without direct operator handling of untreated waste or manual lifting of loaded bins. Each bin features removable anti-stick plates that limit softened plastic buildup on the interior walls, helping reduce cleaning requirements and shorten turnaround times between cycles. A hydraulically operated chamber door seals under PLC control, while safety interlocks prevent opening when residual pressure remains inside the vessel. This design supports reliable batch processing across multiple shifts in centralized medical waste treatment facilities.\u003c\/p\u003e\n\u003cp\u003eAn integrated condensation and deodorization tower treats process exhaust before discharge. Malodorous steam passes through condensation and deodorization stages, preventing untreated process steam from venting directly into the surrounding area and helping control odors at facilities located near occupied buildings or residential zones. Using steam as the sole treatment agent eliminates the need for chemical sterilization agents and reduces associated chemical storage, exposure controls, and secondary hazardous effluent management. Automated cycle monitoring and treatment records also support operational traceability and regulatory reporting requirements.\u003c\/p\u003e\n\u003ch2\u003eHigh-Vacuum Medical Waste Autoclave – ToronMW™ A Applications\u003c\/h2\u003e\n\u003cp\u003eThe ToronMW™ A High-Vacuum Medical Waste Autoclave is designed for centralized medical waste treatment operations that collect infectious waste from multiple sources and require high-volume batch sterilization. With cycle capacities of up to 9,600 L, it supports large-scale waste processing for healthcare networks, industrial facilities, and regional waste management services.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCentral Medical Waste Treatment Plants: High-volume steam sterilization of infectious waste collected from hospitals, clinics, and healthcare facilities across cities or regions, with treatment capacities of up to 9,600 L per cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedical Waste Management Contractors: Centralized treatment infrastructure for waste service providers managing collection and disposal contracts for hospital networks, municipalities, and commercial healthcare operators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge Hospital Systems and Medical Campuses: Centralized sterilization of regulated medical waste generated across multiple hospital buildings, departments, and affiliated healthcare facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRegional Healthcare Networks: Shared medical waste treatment facilities serving clinics, outpatient centers, and smaller healthcare providers that require access to high-capacity sterilization systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePharmaceutical and Biotechnology Manufacturing: Batch treatment of contaminated production consumables, filter media, and laboratory waste generated during pharmaceutical and biotechnological processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClinical and Research Laboratories: Steam sterilization of biological culture waste, specimen containers, and contaminated laboratory materials before approved disposal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVeterinary Hospitals and Animal Research Facilities: Treatment of contaminated bedding, animal tissues, and disposable materials generated by veterinary care, diagnostic testing, and research activities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuarantine and Border Control Facilities: Processing of regulated medical and biological waste at airports, seaports, border inspection stations, and quarantine centers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutbreak Management and Emergency Response: Additional medical waste sterilization capacity during infectious disease outbreaks, public health emergencies, and disruptions to routine waste collection or treatment services.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHigh-Vacuum Medical Waste Autoclave – ToronMW™ A Key Features\u003c\/h2\u003e\n\u003cp\u003eThe ToronMW™ A High-Vacuum Medical Waste Autoclave combines deep pre-vacuum technology, automated waste handling, and integrated exhaust treatment to support efficient, high-capacity medical waste sterilization at centralized treatment facilities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRapid Deep Pre-Vacuum System: A single pre-vacuum cycle reduces chamber pressure to -0.9 bar within five minutes, removing trapped air to promote effective steam penetration and support high-throughput waste treatment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated Condensation and Deodorization Tower: Exhaust steam undergoes condensation and deodorization before release, helping control unpleasant odors and supporting installations near occupied buildings and residential areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControlled Process Steam Discharge: The exhaust treatment system prevents untreated, malodorous process steam from venting directly into the surroundings, helping reduce odor-related concerns at urban waste treatment facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnti-Stick Autoclave Bins: Removable anti-stick plates help prevent softened plastics from adhering to bin walls, reducing manual cleaning requirements and improving turnaround between treatment cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated Bin Loading and Unloading: An integrated handling platform moves wheeled bins into and out of the autoclave chamber, reducing manual lifting and minimizing operator contact with untreated medical waste.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHydraulically Operated Chamber Door: The heavy-duty hydraulic door provides controlled opening and closing for secure chamber sealing during repeated treatment cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePLC-Controlled Safety Interlocks: The programmable logic controller (PLC) manages door operation and prevents opening while residual chamber pressure remains, supporting safe operating procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical-Free and Radiation-Free Sterilization: Steam serves as the treatment medium, eliminating the need for chemical sterilization agents or radiation-based processing and reducing associated storage and exposure-control requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo Secondary Hazardous Treatment Effluent: Steam-based processing avoids the hazardous liquid effluent associated with certain chemical treatment methods, simplifying waste handling and plant operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple Treatment Capacity Configurations: Five configurations provide cycle capacities ranging from 800 L to 9,600 L, allowing facilities to select a system suited to their waste volume, bin arrangement, and throughput requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eSaturated steam sterilization relies on the latent heat released when steam condenses on cooler surfaces within a medical waste load. As steam returns to liquid water, it transfers substantial thermal energy directly to the surrounding material. This moist heat denatures essential microbial proteins and damages nucleic acids, inactivating vegetative bacteria, fungi, viruses, mycobacteria, and bacterial spores when validated time and temperature conditions are achieved. Compared with dry heat sterilization, saturated steam provides efficient heat transfer and effective microbial inactivation at lower temperatures and shorter exposure times.\u003c\/p\u003e\n\u003cp\u003eAir removal is a critical factor in medical waste autoclave performance. According to Dalton's law of partial pressures, the total pressure inside a chamber containing both air and steam is the sum of their individual partial pressures. Trapped air reduces the partial pressure of steam, potentially lowering the actual steam temperature below the value expected from the total chamber pressure. Air also acts as a thermal barrier, creating insulating pockets within densely packed bags and irregular waste loads. These pockets can restrict heat transfer and prevent uniform sterilization, particularly at the center of the load. Gravity displacement alone may not adequately remove trapped air from complex medical waste arrangements.\u003c\/p\u003e\n\u003cp\u003eThe ToronMW™ A High-Vacuum Medical Waste Autoclave addresses this challenge through a single deep pre-vacuum stage that reduces chamber pressure to -0.9 bar within five minutes. This pressure reduction removes most of the air from the chamber before steam admission, allowing the incoming steam to displace and dilute the residual air. The single-stage vacuum process supports efficient air removal without the extended duration associated with multiple vacuum pulses. Once steam enters the chamber, it can penetrate bagged waste and reach internal load surfaces more effectively, supporting consistent heat distribution and reliable sterilization when the specified operating conditions are maintained.\u003c\/p\u003e\n\u003ch2\u003eHigh-Vacuum Medical Waste Autoclave - ToronMW™ A Technical Specifications\u003c\/h2\u003e\n\u003ch3\u003eProcess Performance\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"610\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilization Method\u003c\/td\u003e\n\u003ctd\u003eSaturated steam, pre-vacuum type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Vacuum Level\u003c\/td\u003e\n\u003ctd\u003e-0.9 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Vacuum Time\u003c\/td\u003e\n\u003ctd\u003e5 minutes (single draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment Capacity Range\u003c\/td\u003e\n\u003ctd\u003e800 L to 9,600 L per cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput Range\u003c\/td\u003e\n\u003ctd\u003e120 kg\/h to 1,400 kg\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExhaust Treatment\u003c\/td\u003e\n\u003ctd\u003eCondensation and deodorization tower, no process steam emission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoading\u003c\/td\u003e\n\u003ctd\u003eAutomatic bin loading and unloading platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor\u003c\/td\u003e\n\u003ctd\u003eHydraulic, PLC-controlled with safety interlocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment Agent\u003c\/td\u003e\n\u003ctd\u003eSaturated steam (chemical-free, radiation-free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Range\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"853\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eToronMW™ A-800\u003c\/th\u003e\n\u003cth\u003eToronMW™ A-1600\u003c\/th\u003e\n\u003cth\u003eToronMW™ A-3000\u003c\/th\u003e\n\u003cth\u003eToronMW™ A-6000\u003c\/th\u003e\n\u003cth\u003eToronMW™ A-9600\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment Capacity (L\/cycle)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003e1,600\u003c\/td\u003e\n\u003ctd\u003e3,000\u003c\/td\u003e\n\u003ctd\u003e6,000\u003c\/td\u003e\n\u003ctd\u003e9,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposal Weight* (kg\/h)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003ctd\u003e1,400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions L×W×H (m)\u003c\/td\u003e\n\u003ctd\u003e2.0 × 2.0 × 2.3\u003c\/td\u003e\n\u003ctd\u003e3.3 × 2.0 × 2.3\u003c\/td\u003e\n\u003ctd\u003e5.4 × 2.2 × 2.3\u003c\/td\u003e\n\u003ctd\u003e9.3 × 2.2 × 2.3\u003c\/td\u003e\n\u003ctd\u003e9.4 × 2.9 × 2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (ton)\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e3.1\u003c\/td\u003e\n\u003ctd\u003e4.3\u003c\/td\u003e\n\u003ctd\u003e6.4\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power† (kW)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e* Disposal weight is calculated at a waste density of 100 kg\/m³. Actual disposal weight varies with local waste density and loading method.\u003c\/p\u003e\n\u003cp\u003e† The source lists rated power as two grouped values (4 kW and 6 kW) without a clear per-model breakdown. Confirm the allocation for the selected model before quoting.\u003c\/p\u003e\n\u003ch3\u003eStandard Configuration\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"514\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Chamber\u003c\/td\u003e\n\u003ctd\u003eHorizontal steam sterilization chamber, bin-loaded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum System\u003c\/td\u003e\n\u003ctd\u003eHigh-vacuum pump reaching -0.9 bar in 5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoclave Bins\u003c\/td\u003e\n\u003ctd\u003eWheeled bins with dismountable anti-stick liner plates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoading System\u003c\/td\u003e\n\u003ctd\u003eAutomatic bin loading and unloading platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor System\u003c\/td\u003e\n\u003ctd\u003eHydraulic autoclave door with PLC-controlled interlocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExhaust System\u003c\/td\u003e\n\u003ctd\u003eCondensation and deodorization tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003ePLC cycle control with operator interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumentation\u003c\/td\u003e\n\u003ctd\u003eCycle records for regulatory reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Torontech","offers":[{"title":"Default Title","offer_id":51032969871599,"sku":null,"price":100.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/files\/High-Vacuum-Medical-Waste-Autoclave.webp?v=1791888735"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5291\/9023\/collections\/medical-waste-autoclave-shredder.webp?v=1791887139","url":"https:\/\/shop.torontech.com\/es\/collections\/medical-waste-treatment.oembed","provider":"Torontech","version":"1.0","type":"link"}